APC Smart-UPS VT Maintenance Bypass Panel 10-30kVA 208V Wall Mount


APC Smart-UPS VT Maintenance Bypass Panel 10-30kVA 208V Wall Mount

Professional maintenance bypass panel for APC Smart-UPS VT 10-30kVA systems, enabling safe UPS maintenance and replacement without powering down critical loads, with 208V three-phase wall-mount design.

The APC Smart-UPS VT Maintenance Bypass Panel provides essential service continuity for Smart-UPS VT 10kVA, 15kVA, 20kVA, and 30kVA systems, allowing UPS maintenance, repair, or replacement while maintaining continuous power to connected equipment. Features three-phase 208V configuration, wall-mount design, manual bypass switches, clear status indicators, mechanical interlocks for safety, and current rating matching UPS capacity. Essential for data centers, hospitals, financial institutions, and mission-critical facilities where zero downtime is required during UPS service operations. Professional installation required for high-voltage three-phase systems.

Specifications:

  • Compatibility: Smart-UPS VT 10-30kVA
  • Voltage: 208V three-phase
  • Configuration: Manual maintenance bypass
  • Current Rating: Matches UPS capacity (up to 145A at 30kVA)
  • Form Factor: Wall-mount enclosure
  • Safety: Mechanical interlocks
  • Indicators: Status LEDs
  • Operation: Manual bypass switching
  • Brand: APC by Schneider Electric
  • Application: UPS service continuity

Critical service infrastructure for high-availability UPS installations.

1,110,000.00

APC Smart-UPS VT Maintenance Bypass Panel 10-30kVA 208V Wall Mount

The APC Smart-UPS VT Maintenance Bypass Panel represents essential infrastructure for enterprise-grade UPS installations, providing the critical capability to perform UPS maintenance, repair, battery replacement, or system upgrades without interrupting power to connected mission-critical equipment, ensuring absolute continuity of operations during service events.

This professional-grade bypass panel is engineered specifically for APC Smart-UPS VT series three-phase UPS systems from 10kVA to 30kVA, delivering the service flexibility and operational reliability required in data centers, hospitals, financial institutions, and other environments where downtime is not an option.

Key Features

  • Smart-UPS VT 10-30kVA compatibility
  • Three-phase 208V operation
  • Manual maintenance bypass switching
  • Wall-mount enclosure design
  • Mechanical interlock safety
  • Clear status indicators
  • Current rating to 145A (30kVA)
  • Professional-grade construction
  • Lockable switches
  • Bypass mode isolation
  • Hot-service capability

Maintenance Bypass Function

Critical Service Capability:

  • Service UPS without downtime
  • Continuous power to loads
  • UPS isolation for safety
  • Battery replacement capability
  • System upgrade support
  • Repair without interruption
  • Planned maintenance enablement

Bypass Operation:

  • Transfer loads to bypass
  • Isolate UPS from power
  • Perform maintenance safely
  • Return UPS to service
  • Transfer loads back to UPS
  • Seamless transitions
  • Zero load interruption

Compatible UPS Systems

Smart-UPS VT Series:

  • Smart-UPS VT 10kVA (SUVTP10KH)
  • Smart-UPS VT 15kVA (SUVTP15KH)
  • Smart-UPS VT 20kVA (SUVTP20KH)
  • Smart-UPS VT 30kVA (SUVTP30KH)
  • Three-phase models
  • 208V configurations
  • Wall-mount and rack variations

Three-Phase 208V Configuration

Electrical Specifications:

  • Input: 208V three-phase
  • Output: 208V three-phase
  • Frequency: 50/60 Hz
  • Current capacity: Up to 145A
  • Wire configuration: 3-phase + neutral + ground
  • Circuit breaker protection

Three-Phase Benefits:

  • Higher power capacity
  • Balanced load distribution
  • Efficiency at scale
  • Enterprise-grade power
  • Commercial standard
  • Industrial applications

Manual Bypass Switching

Switch Operation:

  • Manual bypass switches
  • Clear switching sequence
  • Mechanical interlocks
  • Safety procedures
  • Trained operator required
  • Sequential operation
  • Lockout/tagout compatible

Switching Sequence:

  1. Verify bypass source quality
  2. Close bypass input switch
  3. Transfer to bypass mode
  4. Open UPS output switch
  5. Open UPS input switch
  6. UPS isolated for service
  7. Reverse for return to normal

Wall-Mount Design

Space-Efficient:

  • Wall-mounted enclosure
  • Separate from UPS
  • Near UPS installation
  • Organized layout
  • Professional appearance
  • Accessible mounting
  • Service-friendly location

Installation Location:

  • Adjacent to UPS
  • Accessible by operators
  • Adequate service clearance
  • Lighting for visibility
  • Secure location
  • Environmental protection

Mechanical Interlock Safety

Safety Systems:

  • Mechanical interlocks
  • Prevents switch errors
  • Enforces switching sequence
  • Protects personnel
  • Prevents equipment damage
  • UL/safety compliant
  • Fool-proof operation

Interlock Functions:

  • Cannot bypass without source
  • Cannot isolate under load incorrectly
  • Prevents backfeed
  • Ensures proper sequence
  • Emergency stop capability

Status Indicators

Visual Feedback:

  • LED status indicators
  • Power presence indicators
  • Bypass mode indication
  • Fault/alarm indicators
  • Switch position status
  • Clear visibility
  • At-a-glance monitoring

Current Rating

Capacity Specifications:

  • 10kVA: ~28A three-phase
  • 15kVA: ~42A three-phase
  • 20kVA: ~56A three-phase
  • 30kVA: ~84-145A three-phase (varies)
  • Continuous rated
  • UL listed capacity

Professional-Grade Construction

Build Quality:

  • Heavy-duty steel enclosure
  • Industrial-grade switches
  • Powder-coated finish
  • Robust construction
  • Corrosion resistance
  • Long-term reliability
  • NEMA-rated enclosure

Lockable Switches

Security Features:

  • Lockable switch handles
  • Prevent unauthorized operation
  • Maintenance security
  • Access control
  • Safety compliance
  • Operational integrity

Ideal Applications

Data Centers:

  • Enterprise data centers
  • Colocation facilities
  • Cloud infrastructure
  • Server farms
  • High-availability systems
  • 24/7 operations

Healthcare Facilities:

  • Hospitals
  • Medical centers
  • Surgery centers
  • Diagnostic imaging
  • Critical care units
  • Life safety systems

Financial Institutions:

  • Banking data centers
  • Trading floors
  • Financial processing
  • ATM networks
  • Transaction systems
  • Security operations

Industrial Facilities:

  • Manufacturing plants
  • Process control
  • Automation systems
  • Production lines
  • Quality control systems
  • Industrial IT

Telecommunications:

  • Telecom central offices
  • Cell tower sites
  • Network operations centers
  • Switching facilities
  • Broadcast facilities
  • Emergency communications

Government & Critical Infrastructure:

  • Government facilities
  • Emergency services
  • Public safety systems
  • Utilities control
  • Transportation systems
  • Defense installations

Why Maintenance Bypass is Critical

Business Continuity:

  • Zero downtime during service
  • Planned maintenance flexibility
  • Emergency repair capability
  • System upgrade without outage
  • Battery replacement continuity
  • Insurance compliance
  • SLA achievement

Operational Benefits:

  • Schedule maintenance anytime
  • No service windows required
  • No load impact
  • Reduced risk
  • Professional service access
  • Extended UPS lifespan

Installation Requirements

Professional Installation Essential:

  • Licensed electrician required
  • Three-phase experience mandatory
  • UPS manufacturer training recommended
  • High-voltage certification
  • Code compliance critical
  • Inspection required

Installation Considerations:

  • Wall mounting location
  • Service clearances (36″ minimum)
  • Cable routing
  • Proper grounding
  • Labeling and documentation
  • Safety signage
  • Operating procedures posted

Bypass Panel Dimensions

Physical Specifications:

  • Height: Typically 24-36 inches
  • Width: Typically 18-24 inches
  • Depth: Typically 8-12 inches
  • Weight: 50-100 lbs
  • Wall-mount configuration
  • NEMA enclosure

Electrical Connections

Wiring Configuration:

  • Input from utility/generator
  • Output to UPS input
  • Bypass to load
  • UPS output connection
  • Proper wire sizing critical
  • Color-coded connections
  • Torque specifications

Operating Procedures

Standard Operating Procedures Required:

  • Normal operation mode
  • Transfer to bypass sequence
  • UPS isolation procedure
  • Return to normal sequence
  • Emergency procedures
  • Lockout/tagout procedures
  • Documentation requirements

Safety Requirements

Critical Safety:

  • High-voltage three-phase
  • Arc flash hazard
  • Qualified personnel only
  • Proper PPE required
  • Lockout/tagout mandatory
  • Clear procedures
  • Regular training

Safety Equipment:

  • Arc flash PPE
  • Insulated tools
  • Voltage testers
  • Safety barriers
  • Warning signs
  • Emergency shutdown

Maintenance and Testing

Regular Maintenance:

  • Annual inspection
  • Contact cleaning
  • Torque verification
  • Mechanical operation test
  • Indicator verification
  • Interlock testing
  • Documentation updates

What’s Included

  • Maintenance bypass panel enclosure
  • Manual bypass switches
  • Mechanical interlocks
  • Status indicator LEDs
  • Mounting hardware
  • Installation manual
  • Operating procedures guide
  • Safety labels

UPS system and electrical installation sold separately

Compliance & Standards

Certifications:

  • UL Listed
  • NEC compliant
  • NFPA standards
  • OSHA compliant
  • Local code compatible
  • Safety certified
  • Professional-grade

Warranty & Support

  • APC standard warranty
  • Technical support
  • Installation assistance
  • Training available
  • Service contracts
  • Replacement parts
  • Global support network

Integration with Smart-UPS VT

System Integration:

  • Factory coordination
  • Matched ratings
  • Compatible design
  • Tested configuration
  • System warranty
  • Coordinated support

Documentation Requirements

Critical Documentation:

  • Single-line diagram
  • Operating procedures
  • Maintenance logs
  • Training records
  • Safety procedures
  • Emergency contacts
  • Inspection records

Training Requirements

Operator Training:

  • Bypass operation procedures
  • Safety protocols
  • Emergency procedures
  • Maintenance coordination
  • Documentation requirements
  • Hands-on practice
  • Periodic refresher

Essential maintenance infrastructure for zero-downtime UPS service – the APC Smart-UPS VT Maintenance Bypass Panel delivers professional-grade manual bypass capability for Smart-UPS VT 10-30kVA three-phase systems, featuring mechanical interlocks, status indicators, and wall-mount design rated for 208V three-phase up to 145A, enabling safe UPS maintenance, repair, battery replacement, and system upgrades without interrupting power to mission-critical loads in data centers, hospitals, and facilities requiring absolute uptime. Professional installation and trained operators required.

Category:

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “APC Smart-UPS VT Maintenance Bypass Panel 10-30kVA 208V Wall Mount”

There are no reviews yet.

Select your currency

Select at least 2 products
to compare